Professional chimney service

Pellet Stove Repair in Yorba Linda

Ask About This Job

Draft Tested on Every Visit
Written Price Before Work
Photos With Each Report
CO Reading on Gas Units
Levels Per NFPA 211
Based in Yorba Linda
Draft Tested on Every Visit
Written Price Before Work
Photos With Each Report
CO Reading on Gas Units
Levels Per NFPA 211
Based in Yorba Linda

What This Visit Covers

When a pellet stove puffs smoke into the room or shuts down on a fault, the cause is often air: ash packed in the exhaust path, a weak combustion blower or a clogged vent. Feed and ignition faults come next. We clean the exhaust path and vent pipe, test the blower, igniter, feed motor and sensors in turn, and replace only the part that has failed. Where a stove is beyond sensible repair, we say so in writing.

Exhaust path and vent pipe cleared of ash
Combustion blower tested for pull
Feed motor and igniter checked in turn
Sensor and board fault codes read
Smoke smell in the room traced to its source

Smoke and Smell From a Pellet Stove

Unlike a fireplace, which depends on hot air rising, a pellet stove pushes its exhaust out with a fan. That turns the vent pipe into a pressurized pipe. A joint that has lost its sealant, a gasket on the door or ash pan that has flattened, or a crack in the pipe lets smoke into the room whenever the fan runs, and owners notice it as a faint smell or a haze near the stove. It gets worse when ash builds up in the passages inside the stove, because the fan then has to push harder against the blockage. A power cut is the other moment smoke appears. When the fan stops with a fire still smoldering, the exhaust has to find its own way out, and a vent run with too little upward rise lets it drift back into the room instead. We look at the vent layout with that in mind and suggest changes where the rise is too short.

Shutdowns are the other common complaint. The stove watches its own fire through a few sensors: one that checks the exhaust is moving, one that checks the fire is hot enough, and one that guards against overheating. When any of them reports a problem, the control stops the feed and the stove goes out. Often the sensor is right. Ash packed into the exhaust path or a blocked outside vent stops the airflow, and the stove shuts itself off to keep smoke out of the house. Other times the sensor or its hose has failed and the stove shuts down with nothing actually wrong. Ignition faults show up as a pot full of unburnt pellets and a stove that gives up after a few minutes. Feed faults show up as a fire that fades and dies. Each of these tests differently, and we test before ordering any part.

The Repair Visit and How It Is Priced

A repair visit usually starts with a thorough clean, because so many pellet stove faults come back to ash. The fire pot, the passages around it and the exhaust path are cleared, and the vent pipe is brushed to the outside. Then we test. The fans are run and listened to for bearing noise, the sensors and their hoses are checked, the igniter is tested for heat, and the feed motor is run to see that it turns and delivers pellets. Door and glass gaskets are checked by closing the door on a strip of paper and pulling, which shows where the seal has gone slack. Finally we light the stove and run it through a cycle, watching the flame and checking the room air for carbon monoxide. When the stove is vented into an old masonry chimney, we look at how the pipe runs up it and whether it is properly connected at the top.

Repairs are priced in writing once we know which part has failed, and nothing is fitted without your agreement. Some stoves were made by companies that are no longer around, and their control boards and motors can be hard to get. When that is the case, we say so and set out the cost of keeping the stove going against replacing it. When you book, the label on the back or side of the stove and whatever the display reads help us bring the likely parts on the first trip. A stove that smokes into the room should not be run until the leak is found, since pellet exhaust carries carbon monoxide like any other fire. Owners in Yorba Linda and Corona mostly run pellet stoves on cool evenings, which makes the start of the season a good time for this check.

The Upton Chimney Solutions Routine

Draft Watched

Smoke pencil or test fire at the opening

Fumes Measured

CO meter running on gas units

Prices on Paper

Each fix priced before anyone starts

Cause Shown

You see the fault we found, in person or in photos

Other Jobs We Handle

Chimney Sweep

Creosote narrows a flue until smoke backs into the room; brushing clears that path and a test fire proves it.

Details

Chimney Inspection

Reasons a chimney smokes, smells or stalls, looked for from the opening up to the cap and set out in writing.

Details

Chimney Repair

Broken tile, open joints, a split crown or a loose top: the faults that spoil draft or let rain in, put right.

Details

Fireplace Inspection

Soot on the face, a fire that will not settle, a draft from the hearth: the room side of the fireplace checked for causes.

Details

Fireplace Repair

Fixes for fireplaces that smoke at the face, smell between fires or refuse to hold a flame, starting with the reason.

Details

Chimney Level 2 Inspection

Recorded video of the whole flue plus the attic and underfloor stretches, for sales, quakes, fires and new appliances.

Details

Chimney Cap Installation

Stainless or copper tops that stop rain, birds and gusts pushing down the flue, fixed firm against Santa Ana wind.

Details

Chimney Flashing Repair

New roof-line metal for chimneys that drip into the attic or stain the ceiling beside the fireplace after rain.

Details

Chimney Masonry Repair

Repointing, brick replacement and crack repair that keep water out of the stack and the flue walls standing true.

Details

Chimney Rebuilds

A new stack from the point where the brick holds firm, with a flue sized to the fireplace it serves.

Details

Fireplace Cleaning

Room-side cleaning of the firebox, doors and face, with a record of the soot marks that show where smoke escapes.

Details

Gas Fireplace Cleaning

Yearly cleaning for gas fireplaces and inserts so the flame burns blue, the glass stays clear and fumes go outside.

Details

Gas Fireplace Repair

Fixes for gas units that refuse to light, drop out after a minute, smell of fumes or blacken the glass.

Details

Fireplace Remodel

New faces, hearths and mantels that keep safe distances from the opening and leave the draw working as it should.

Details

Fireplace Inserts

A steel firebox behind glass with its own liner, a common answer for open fireplaces that smoke or chill the room.

Details

Wood Stove Repair

Repairs for wood stoves that leak smoke at the door, burn too fast or stop drawing once the fire settles.

Details

Gas Logs

Ceramic logs on a gas burner for a fireplace you no longer want to feed, set up so the fumes go where they should.

Details

Chimney Seismic Retrofit

Work that ties a tall brick stack to the house or lightens its top, so a big quake is less likely to drop it.

Details

Chimney Crown Repair

Crack sealing or a newly poured top for chimneys whose cement cap lets rain soak down into the brick and flue.

Details

Dryer Vent Cleaning

Lint cleared from the full duct run, wall hood to machine, for dryers that run hot or need two cycles to finish.

Details

Chimney Liner Installation

New stainless flue run inside the old chimney, for cracked tile or a flue too big or too small to draw.

Details

Chimney Leak Repair

Leak tracing for chimneys that drip, stain the ceiling or smell musty after rain, with the fix aimed at the source.

Details

Chimney Waterproofing

A siloxane repellent on repaired brick so the stack sheds rain and stops feeding damp smells into the house.

Details

Chimney Damper Repair

Dampers that stick, rattle, leak cold air or open only partway, freed and adjusted or replaced at the flue top.

Details

Chimney Chase Cover

A stainless top made to measure for framed chimneys whose old sheet top has rusted, sagged or started to leak.

Details
Call (657) 231-4031